Specification
Capacity 250 L
Temp. Range RT +5-60°C
Temp. Accuracy 0.1°C
Temp. Uniformity <±0.5°C
Temp. Fluctuation <±0.2°C
Temp. Resolution 0.1°C
CO2 Range 0-19.9%
CO2 Accuracy 0.10%
CO2 Sensor TCD CO2 Sensor
CO2 Control Method TCD
CO2 Recovery Time ≤concentration x 1.2 min
Display LCD display
Jacket Type Air Jacketed
Humidifying Method Natural Evaporation
Filter HEPA filter
Inner Chamber Material Mirror Finished Stainless Steel
Outer Chamber Material Plastic Coated Cold-Rolling Steel
Shelves 3
Chamber Dimension 600x600x770 mm
Overall Dimension 840x775x1175 mm
Power 800 W
Power Supply 220V, 50Hz
Catalog No. 9341119127

CO2 Incubator Air Jacketed LACI-303

Details

• Mirror finished stainless steel interior and plastic coated cold-rolling steel exterior

• Double seal door structure with magnetic seal at the outer door

• Silicone seal strips between working chamber and inner glass door ensures air-tight sealing

• Door heating control system provides frost-free inner glass door

• Long lasting, low noise centrifugal fan to ensure temperature uniformity

• Microprocessor intelligent controller

• Temperature, humidity and CO2 concentration displayed on LCD screen

• Audio visual alarm over temperature control

• TCD CO2 concentration sensor with precise sensitivity

• Humidity sensor displays real-time data

• UV light for effective killing of bacteria, mold and mycoplasma

• High temperature moist heat sterilization at 90°C

• HEPA offers 99.998% filtration efficiency for 0.3µm particulate

• Microcomputer auto-restrain control system avoids temperature fluctuation

• Assistant control system plays a key role during invalidation of main control system

• Audio visual alarm for over temperature control

• Data can be stored and recovered on power or system failure

• RS485 interface

Application

Labocon CO2 Incubator Air Jacketed is suitable for use in research and production of microorganisms; for cells, tissue and bacteria cultivation; in immunology, oncology, genetics and biological engineering.

Your Recent History View All
    • Capacity: 0.5-500 ml
    • Frequency: 20-25 KHz
    • Probe Diameter: 1/4 inch
    • Optional Probe(ɸ mm): 2,3,6,8,10,12,15
    • Ultrasonic Power: 650 W
    • Wavelength Range: 190-900 nm
    • Wavelength Accuracy: Better than ±0.25 nm
    • Spectral Bandwidth: 0.1, 0.2, 0.4, 1.2 nm
    • Resolution: Less than 30%
    • Baseline Stability: 0.004A/30min
    • Wavelength Range: 190-1100 nm
    • Wavelength Accuracy: ±0.1 nm (656.1nm D2); ±0.5 nm (whole wavelength range)
    • Wavelength Repeatability: ±0.15 nm
    • Spectral Resolution: 0.1 nm
    • Spectral Bandwidth: 1.8 nm/4 nm
    • Wavelength Range: 200-1100 nm
    • Wavelength Accuracy: ±1 nm
    • Wavelength Repeatability: ±0.5 nm
    • Spectral Bandwidth: 2 nm, 4 nm
    • Stability: ±0.002 A/hr. at 500 nm, 0 A